Sign In | Join Free | My hfcletter.com
hfcletter.com
Products
Search by Category
Wholesale Marketplace
Home > Woodworking Machinery >

400 kW Perkins Diesel Generator , 3 Pole MCCB , P450E1 , Electronic

Categories Perkins Diesel Generator
Place of Origin: China
Brand Name: Perkins
Model Number: JP-P450E1
MOQ: 20-30 pieces
Price: Negotiable
Packaging Details: Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time: 3-5 days on receipt of official sales contract
Payment Terms: L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability: 500 pieces per Month
Port:: HongKong or ShenZhen,ShangHai,Dalian as required
Certification: CE/RoHs/ISO9001
Company Info.
Jackwell Limited
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    400 kW Perkins Diesel Generator , 3 Pole MCCB , P450E1 , Electronic


    1. Standby power: 360.0 kW

    2.Engine Make & Model: Perkins 2306C-E14TAG3

    3.Alternator Model: LL6014F

    4.Circuit Breaker Type: 3 Pole MCCB

    5.Cooling Method: Water Governing

    6.Type: Electronic Governing

    7.Class: ISO 8528 G2

    8.Compression Ratio: 15.9:1

    9.Displacement: l (cu.in) 14.6 (890.9)

    10.Bore/Stroke: mm (in) 137.0 (5.4)/165.0 (6.5)

    11.Moment of Inertia: kg m² (lb. in²) 3.43 (11721)


    400 kW P450E1 Perkins Diesel Generator , 3 Pole MCCB


    Output Ratings

    Generating Set Model

    - P450E1

    Prime* Standby*

    380-415V, 50 Hz

    • 450.0 kVA
    • 360.0 kW

    480V, 60 Hz

    • 500.0 kVA
    • 400.0 kW
    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.


    Technical Data

    Engine Make & Model:

    Perkins 2306C-E14TAG3

    Alternator Model:

    LL6014F

    Base Frame Type:

    Heavy Duty Fabricated Steel

    Circuit Breaker Type:

    3 Pole MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    1500 1800

    Fuel Tank Capacity: litres (US gal)

    820 (216.6)

    Fuel Consumption: - l/hr (US gal/hr)

    - -

    Fuel Consumption: P450E1 l/hr (US gal/hr)

    95.4 (25.2) 103.2 (27.3)

    P450E1


    Engine Technical Data


    Physical Data


    Manufacturer: Perkins

    Model: 2306C-E14TAG3

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged Air To Air Charge Cooled

    Cooling Method: Water

    Governing Type: Electronic

    Governing Class: ISO 8528 G2

    Compression Ratio: 15.9:1

    Displacement: l (cu.in) 14.6 (890.9)

    Bore/Stroke: mm (in) 137.0 (5.4)/165.0


    (6.5) Moment of Inertia: kg m² (lb. in²) 3.43 (11721)

    Engine Electrical System:

    -Voltage/Ground: 24/Negative

    -Battery Charger Amps: 70

    Weight: kg (lb) - Dry: 1690 (3726)

    - Wet: 1792 (3951)


    Air System 50 Hz 60 Hz


    Air Filter Type: Replaceable

    Element Combustion Air Flow:m³/min (cfm)

    -Standby: 27.5 (971) 40.7 (1437)

    -Prime: -

    - Max. Combustion Air Intake

    Restriction: kPa (in H2O) 6.2 (24.9) 6.2 (24.9)

    Radiator Cooling Air Flow:m³/min (cfm) 444.0 (15680) 600.0 (21189)

    External Restriction to Cooling Air Flow: Pa (in H2O) 188 (0.8) 188 (0.8)


    Cooling System 50 Hz 60 Hz


    Cooling System Capacity:

    l (US gal) 47.0 (12.4) 47.0 (12.4)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: 151.5 (8616) 166.5 (9469)

    -Prime: -

    - Heat Radiation to Room:kW (Btu/min)

    -Standby: 38.8 (2207) 47.0 (2673)

    -Prime: -

    - Radiator Fan Load: kW (hp) 9.0 (12.1) 17.0 (22.8)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).


    Performance 50 Hz 60 Hz


    Engine Speed: RPM 1500 1800

    Gross Engine Power: kW (hp)


    -Standby: 396.0 (531.0) 447.0 (599.0)

    -Prime: 353.0 (473.0) 393.0 (527.0)

    BMEP: kPa (psi)

    -Standby: 2170.0 (314.8) 2042.0 (296.2)

    -Prime: 1935.0 (280.7) 1795.0 (260.4)

    Regenerative Power: kW 27.0 39.0


    Lubrication System


    Oil Filter Type: Eco, Full Flow

    Total Oil Capacity l (US gal): 68.0 (18.0)

    Oil Pan l (US gal): 60.0 (15.9)

    Oil Type: API CG4 15W-40

    Cooling Method: Water


    Fuel System


    Fuel Filter Type: Eco

    Replaceable Element Recommended Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)

    110% 100% 75% 50%

    Load Load Load Load


    P450E1


    50 Hz 95.4 (25.2) 71.1 (18.8) 49.3 (13.0)

    60 Hz 103.2 (27.3) 81.5 (21.5) 56.6 (15.0)


    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


    Exhaust System 50 Hz 60 Hz


    Silencer Type: Level 1

    Silencer Model & Qty: SD150 (1)

    Pressure Drop Across Silencer System: kPa (in Hg) 0.01 (0.003) 0.06 (0.018)

    Silencer Noise Reduction Level: dB 19 17

    Max. Allowable Back

    Pressure: kPa (in. Hg) 7.0 (2.1) 7.0 (2.1)

    Exhaust Gas Flow:m³/min (cfm)

    -Standby: 69.3 (2447) 98.4 (3475)

    -Prime: -

    Exhaust Gas Temperature: °C (°F)

    m³/min (cfm)

    -Standby: 514 (957) 434 (814)

    -Prime: - -

    P450E1


    Alternator Performance Data



    Data Item

    50 Hz 60 Hz

    415/240V

    400/230V

    230/115V

    200/115V

    380/220V

    220/110V

    220/127V

    480/277V

    240/139V

    380/220V

    220/110V

    240/120V

    208/120V

    230/115V

    440/254V

    220/127V

    Motor Starting Capability* kVA

    1038

    972

    886

    1150

    1142

    750

    885

    824

    979

    Short Circuit Capacity** %

    300

    300

    300

    300

    300

    300

    300

    300

    300

    Reactances: Per Unit

    Xd X'd X''d

    2.820


    0.130


    0.105

    3.040


    0.140


    0.113

    .370


    0.160


    0.125

    2.510


    0.120


    0.093

    2.820


    0.130


    0.105

    4.490


    0.210


    0.167

    3.750


    0.170


    0.139

    4.050


    0.190


    0.151

    3.350


    0.160


    0.125


    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data


    Physical Data Operating Data

    Manufacturer: FG WILSON

    Overspeed: RPM 2250

    Model: LL6014F

    Voltage Regulation (steady state) (%): + /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class: H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code: 2/3 - 6

    Total Harmonic Content LL/LN: 4.0%

    Wires: 12

    Supression is in line with European Standard

    Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: 22.2 (1262)


    -60 Hz: 24.6 (1399)

    Excitation System: SHUNT

    AVR Model: R448

    P450E1


    Technical Data


    3 Phase Ratings and Performance at 50 Hz, 1500 RPM

    3 Phase Ratings and Performance at 60 Hz, 1800 RPM



    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    - P450E1 - P450E1


    kVA kW

    kVA kW


    kVA kW

    kVA kW

    415/240V

    - -

    450.0 360.0

    480/277V

    - -

    500.0 400.0

    400/230V

    - -

    450.0 360.0

    220/127V

    - -

    500.0 400.0

    380/220V

    - -

    450.0 360.0

    380/220V

    - -

    500.0 400.0

    230/115V

    - -

    450.0 360.0

    240/120V

    - -

    500.0 400.0

    220/127V

    - -

    450.0 360.0

    230/115V

    - -

    500.0 400.0

    220/110V

    - -

    450.0 360.0

    440/254V

    - -

    500.0 400.0

    200/115V

    - -

    450.0 360.0

    220/110V

    - -

    500.0 400.0




    208/120V

    - -

    500.0 400.0




    230/115V

    - -

    500.0 400.0


    Definitions

    Standby Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


    Prime Rating

    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


    Standard Reference Conditions

    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.




    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in)


    Net (+ lube oil)


    3450 (7606)


    Length


    3601 (141.8)

    Wet (+ lube oil & coolant)

    3500 (7716)

    Width

    1150 (45.3)

    Fuel, lube oil & coolant

    4193 (9244)

    Height

    2065 (81.3)

    General Data


    Documents

    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


    Generating Set Standards

    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.



    Warranty

    All equipment carries full manufacturer's warranty.


    Quality 400 kW Perkins Diesel Generator , 3 Pole MCCB , P450E1 , Electronic for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Jackwell Limited
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2018 hfcletter.com. All rights reserved.