T2/Class C SPD/ lightning /Surge Arrester for AC power distribution system, UL1449-4th and IEC61643-11 certified

Categories surge protective device
Brand Name: HIT
Model Number: SP275-3P, SP320-3PN
Certification: UL, KEMA, CE, ROHS
Place of Origin: China
Delivery Time: 4 weeks
enclosure: thermoplastic; extinguishing degree UL94 V-0
Installation: Din rail, DIN 43880
max. discharge current: 40kA 8/20
Nominal discharge current: 20kA 8/20
Nominal voltage: 150Vac, 180Vac, 275Vac, 320Vac, 385Vac, 420Vac, 550Vac, 690Vac
Nominal system: 20/240V; 240/480V singlephase, splt phase, 220Y/127V, 380Y/220V&400Y/230V&415Y/240V&480Y/277V, 600Y/347V Three-phase wye (star) four- wire + ground
Power supply system: 120/240V,240V/480V Three-phase high leg delta, 240V,480V,600V Three-phase delta three-wire + ground, 127V,220&230V&240V&277V,347V,480V, 600V Single-phase two-wire + ground
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    T2/Class C SPD/ lightning /Surge Arrester for AC power distribution system, UL1449-4th and IEC61643-11 certified

    http://www.surge-protective-device.com/index.php?m=Index&a=products_show&id=210


    Prosurge’s SP series surge arrester is IEC61643-11:2011/EN61643-11:2012 approved Type 2 SPD especially designed for low-voltage power supply system surge protection at the boundaries from lightning protection zone 0B-2 and higher.


    It is a din-rail designed surge protective device featuring Prosurge’s global patented design of thermally protected MOV with special arc-extinguish device, providing fast and reliable protection for various power supply systems.

    Built with window fault indication and optional remote alarm contact, it can monitor the operating status of the surge protector.


    General Product Specifications


    Nominal discharge current(8/20) In20 kA
    Maximum discharge current(8/20) Imax40 kA
    Category IEC/VDET2
    Frequency48-62 Hz
    Follow currentMOV model: Nil; GDT model: 100A self cutoff
    Thermal disconnectorInternal: green - normal ; red - failure
    Wire RangeSingle-strand 35mm2; multi-strand 25mm2
    Mounting35mm DIN-Rail
    Degree of ProtectionIP 20
    FlammabilityUL94 V0
    Operating & Storage Temperature– 40℃ to + 80℃
    Remote alarm contactNO/NC/C, Isolated Form C
    Remote alarm contact capability Un/InAC: 250V/0.5A DC: 250V/0.1A; 75V/0.5A
    Remote alarm contact connecting wireMax. 1.5mm2 or # 16AWG


    Single pole SPD:

    Part NoPoleMaximum Continuous
    Operating Voltage, Uc (VAC)
    Voltage Protection Level, Up (V)Application
    L-NL-GN-GL-NL-GN-GL-NL-GN-G
    SP150(-S)11501501500.80.80.8
    SP275(-S)12752752751.41.41.4
    SP275VT(-S)12752752751.41.41.4
    SP320(-S)13203203201.51.51.5
    SP320VT(-S)13203203201.51.51.5
    SP385(-S)13853853851.81.81.8
    SP255T(-S)1--255--1.5

    SPD models using for Single-phase TN/TT system (*PN : GDT Module is used for N-PE pole):

    Part NoPolePower distribution systemNominal
    Voltage
    Maximum Continuous
    Operating Voltage, Uc (VAC)
    Voltage Protection Level, Up (V)
    (VAC)L-NL-GN-GL-NL-GN-G
    SP150/2P(-S)2TN110/120-150150-0.80.8
    SP150/PN(-S)2TN/TT150-255*0.8-1.5
    SP275/2P(-S)2TN220/230-275275-1.41.4
    SP275VT/2P(-S)2-275275-1.41.4
    SP275/PN(-S)2TN/TT220/230275-255*1.4-1.5
    SP275VT/PN (-S)2275-255*1.4-1.5
    SP320/2P(-S)2TN220/230/240-320320-1.51.5
    SP320VT/2P(-S)2-320320-1.51.5
    SP320/PN(-S)2TN/TT220/230/240320-255*1.5-1.5
    SP320VT/PN (-S)2320-255*1.5-1.5
    SP385/2P(-S)2TN220/230/240-385385-1.81.5
    SP385/PN(-S)2TN/TT385-255*1.8-1.5

    SPD models using for Three-phase TN-C system

    Part NoPolePower distribution systemNominal
    Voltage
    Maximum Continuous
    Operating Voltage, Uc (VAC)
    Voltage Protection Level, Up (V)
    (VAC)L-NL-GN-GL-NL-GN-G
    SP150/3P(-S)3TN-C110-150--0.8-
    SP275/3P(-S)3220/230-275--1.4-
    SP275VT/3P(-S)3-275--1.4-
    SP320/3P(-S)3220/230/240-320--1.5-
    SP320VT/3P(-S)3-320--1.5-
    SP385/3P(-S)3220/230/240-385--1.8-

    Part No

    PolePower distribution systemNominal
    Voltage
    Maximum Continuous
    Operating Voltage, Uc (VAC)
    Voltage Protection Level, Up (V)
    (VAC)L-NL-GN-GL-NL-GN-G
    SP150/4P(-S)4TN110-150150-0.80.8
    SP150/3PN(-S)4TN/TT150-255*0.8-1.5
    SP275/4P(-S)4TN220/230-275275-1.41.4
    SP275VT/4P(-S)4-275275-1.41.4
    SP275/3PN(-S)4TN/TT275-255*1.4-1.5
    SP275VT/3PN(-S)4275-255*1.4-1.5
    SP320/4P(-S)4TN220/230/240-320320-1.51.5
    SP320VT/4P(-S)4-320320-1.51.5
    SP320/3PN(-S)4TN/TT320-255*1.5-1.5
    SP320VT/3PN(-S)4320-255*1.5-1.5
    SP385/4P(-S)4TN220/230/240-385385-1.81.8
    SP385/3PN(-S)4TN/TT385-255*1.8-1.5

    Quality T2/Class C SPD/ lightning /Surge Arrester for AC power distribution system, UL1449-4th and IEC61643-11 certified for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Prosurge Electronics Co., Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2018 hfcletter.com. All rights reserved.